Practical implementation of Hilbert-Huang Transform algorithm 认领 引用 被引量:52
1
作者 黄大吉 赵进平 苏纪兰 《Acta Oceanologica Sinica》 SCIE CAS 2003年第1期1-14,共14页
Hilbert-Huang Transform (HHT) is a newly developed powerful method for nonlinear and non-stationary time series analysis. The empirical mode decomposition is the key part of HHT, while its algorithm was protected by N... Hilbert-Huang Transform (HHT) is a newly developed powerful method for nonlinear and non-stationary time series analysis. The empirical mode decomposition is the key part of HHT, while its algorithm was protected by NASA as a US patent, which limits the wide application among the scientific community. Two approaches, mirror periodic and extrema extending methods, have been developed for handling the end effects of empirical mode decomposition. The implementation of the HHT is realized in detail to widen the application. The detailed comparison of the results from two methods with that from Huang et al. (1998, 1999), and the comparison between two methods are presented. Generally, both methods reproduce faithful results as those of Huang et al. For mirror periodic method (MPM), the data are extended once forever. Ideally, it is a way for handling the end effects of the HHT, especially for the signal that has symmetric waveform. The extrema extending method (EEM) behaves as good as MPM, and it is better than MPM for the signal that has strong asymmetric waveform. However, it has to perform extrema envelope extending in every shifting process. 展开更多
关键词 Hilbert-Huang Transform (HHT) signal processing Empirical Mode Decomposition (EMD)
暂未订购 下载PDF
Optimization of the End Effect of Hilbert-Huang transform(HHT) 认领 引用 被引量:5
2
作者 Chenhuan Lv Jun ZHAO +2 位作者 Chao WU Tiantai GUO Hongjiang CHEN 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第3期732-745,共14页
In fault diagnosis of rotating machinery, Hil- bert-Huang transform (HHT) is often used to extract the fault characteristic signal and analyze decomposition results in time-frequency domain. However, end effect occu... In fault diagnosis of rotating machinery, Hil- bert-Huang transform (HHT) is often used to extract the fault characteristic signal and analyze decomposition results in time-frequency domain. However, end effect occurs in HHT, which leads to a series of problems such as modal aliasing and false IMF (Intrinsic Mode Func- tion). To counter such problems in HHT, a new method is put forward to process signal by combining the general- ized regression neural network (GRNN) with the bound- ary local characteristic-scale continuation (BLCC). Firstly, the improved EMD (Empirical Mode Decompo- sition) method is used to inhibit the end effect problem that appeared in conventional EMD. Secondly, the gen- erated IMF components are used in HHT. Simulation and measurement experiment for the cases of time domain, frequency domain and related parameters of Hilbert- Huang spectrum show that the method described here can restrain the end effect compared with the results obtained through mirror continuation, as the absolute percentage of the maximum mean of the beginning end point offset and the terminal point offset are reduced from 30.113% and 27.603% to 0.510% and 6.039% respectively, thus reducing the modal aliasing, and eliminating the false IMF components of HHT. The proposed method caneffectively inhibit end effect, reduce modal aliasing and false IMF components, and show the real structure of signal components accuratelX. 展开更多
关键词 End effect Hilbert-Huang transform HHT)Modal aliasing Boundary local characteristic-scalecontinuation (BLCC) Generalized regression neuralnetwork (GRNN)
暂未订购 下载PDF
Transmission Lines Distance Protection Using Differential Equation Algorithm and Hilbert-Huang Transform 认领 引用
3
作者 Xingmao Liu Zhengyou He 《Journal of Power and Energy Engineering》 2014年第4期616-623,共8页
This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various fa... This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance. 展开更多
关键词 Hilbert-Huang Transform Differential Equation Algorithm Distance Protection Transmission Lines
暂未订购 下载PDF
Efficacy of Hilbert-Huang Transform (HHT) in the Analysis of Instantaneous Low Frequency Waves of Magnetosheath 认领 引用
4
作者 Ekong U. Nathaniel Nyakno J. George +1 位作者 Jewel I. Ibanga Aniekan M. Ekanem 《International Journal of Geosciences》 CAS 2016年第1期11-19,共9页
The flow of supersonic plasma is accompanied by a highly thermalized region called the Magnetoshealth found after the bow shock. Enclosed within this region are different wave modes associated with classes of boundari... The flow of supersonic plasma is accompanied by a highly thermalized region called the Magnetoshealth found after the bow shock. Enclosed within this region are different wave modes associated with classes of boundaries which have been determined by different methods. The efficacy of Hilbert-Huang transform (HHT) is based on the conditionality of allowing for the local analysis of frequencies, which presents the physical meaning of the original signal at that instant. The observed data have been taken from Cluster II Fluxgate Magnetometer (FGM) instrument that provides advantage for the analysis in three dimensions. The result compares favourably with instantaneous frequencies computed using simple Hilbert transform (SHT) with electric field measurements of Cluster II mission already carried out in literatures. The result of this study has shown that HHT provides the best applicability in the magnetosheath data analysis than the wavelet and Fast Fourier Transform (FFT). The application of HHT based on its advantages over other methods is viewed to be very critical in the analysis of multi-frequency signals where different frequencies could be determined distinctively at a point. 展开更多
关键词 Plasma Waves Instantaneous Frequency Empirical Mode Decomposition (EMD) Hilbert-Huang Transform (HHT)
暂未订购 下载PDF
Pulse Wave Analysis in Patients with Coronary Heart Disease Based on Hilbert-Huang Transformation and Time-domain 认领 引用 被引量:4
5
作者 LI Fu-feng WANG Yi-qin +3 位作者 SUN Ren XUE Song YAO Di SHEN Hai-dong 《Chinese Journal of Biomedical Engineering(English Edition)》 CAS 2013年第2期47-54,共8页
Objective: To study the characteristics of pulse tracings in CHD, and objectively evaluate the significance of pulse signal in diagnosis and appreciation of therapeutic effect in patients with coronary heart disease(C... Objective: To study the characteristics of pulse tracings in CHD, and objectively evaluate the significance of pulse signal in diagnosis and appreciation of therapeutic effect in patients with coronary heart disease(CHD), and accordingly provide with theoretic proofs for developing non-invasive technique of pulse diagnosis. Methods: By using the pulse detection system, pulse graphs in CHD patients, patients without CHD and "health" adults were collected and compared. Then characters of the pulse signal were analyzed with Hilbert-Huang transformation routine (HHT) and time-domain method respectively. Results: There existed characteristic change in pulse graph in CHD. ① h1,h3,h4,h3/h1,t,t54 in time domain parameters of pulse graph increased and w1 was widened. ② 44% of C2 wave in HHT display showed chaotic and disorderly wave and irregularly wave amplitude in CHD. And 72% of C5 Wave exhibited in irregular wave with average wave amplitude over 10 gram-forces. These changes were significantly different from health adults. Conclusion: Characteristic wave of pulse graph extracted with methods of time domain or HHT routine might be considered as proofs for diagnosis and differentiation in CHD. Our researches prognosticate that pulse diagnosis can be used as an ancillary determination in occurrence of CHD for reasons of the advantage of convenient operation and non-invasion. 展开更多
关键词 coronary heart disease(CHD) pulse graph Hilbert-Huang transformation(HHT) time-domain method
暂未订购 下载PDF
Analysis of the characteristics of gastrointestinal motility based on Hilbert-Huang transform method 认领 引用 被引量:1
6
作者 黄标 Yan Guozheng 《High Technology Letters》 EI CAS 2008年第1期30-34,共5页
Pressure activity data as an important index of gastrointestinal (GI) motility can be obtained from the wireless radiotelemetry capsule. The Hilbert-Huang transform (HHT) method, which is more effective to process... Pressure activity data as an important index of gastrointestinal (GI) motility can be obtained from the wireless radiotelemetry capsule. The Hilbert-Huang transform (HHT) method, which is more effective to process non-stationary signal, is proposed to identify the characteristics of GI motility. We decompose the pressure activity data into intrinsic mode functions (IMFs), calculate the Hi/bert marginal spectrum and attain the peristalsis characteristics of GI tract. The IMFs represent the peristalses modes of GI tract activity embedded in the pressure data. The time-varying characteristic of the method suggests that the HHT is suitable to accommodate other non-stationary biomedical data analysis. 展开更多
关键词 intrinsic mode function empirical mode decomposition (EMD) Hilbert-Huang transform HHT method gastrointestinal (GI) motility
暂未订购 下载PDF
基于HHT算法的呼吸机运行状态智能监测方法 认领 引用 被引量:2
7
作者 张朝 《吉林大学学报(信息科学版)》 CAS 2025年第2期309-316,共8页
为确保呼吸机正常工作,提出基于希尔伯特变换(HHT:Hilbert-Huang Transform)算法的呼吸机运行状态智能监测方法。首先采用小波神经网络对呼吸机运行信号实施去噪处理;其次,结合HHT算法将去噪后的呼吸机运行信号进行经验模态分解(EMD:Emp... 为确保呼吸机正常工作,提出基于希尔伯特变换(HHT:Hilbert-Huang Transform)算法的呼吸机运行状态智能监测方法。首先采用小波神经网络对呼吸机运行信号实施去噪处理;其次,结合HHT算法将去噪后的呼吸机运行信号进行经验模态分解(EMD:Empirical Mode Decompostion),并将分解后的内禀模式分量(IMF:Intrinsic Mode Function)进行Hilbert谱变换,以此获取信号频谱作为信号特征。最后,将得到的信号频谱放入MLP(Multi-Layer Perceptron)神经网络分类器中,采用反向传播算法对多层感知器(MLP:Multi-Layer Perceptron)神经网络进行训练,以实现呼吸机运行状态识别。实验结果表明,所提方法的去噪效果较好,且监测到的结果和实际频谱一致。同时监测敏感度在96%以上、运行状态识别准确性在95%以上。表明所提方法可以有效监测呼吸机运行状态,监测性能较好。 展开更多
关键词 HHT算法 呼吸机运行状态 小波神经网络 EMD分解 Hilbert谱变换 MLP神经网络分类器
暂未订购 下载PDF
基于HHT和SVM的运动想象脑电识别 认领 引用 被引量:46
8
作者 袁玲 杨帮华 马世伟 《仪器仪表学报》 EI CAS 北大核心 2010年第3期649-654,共6页
对运动想象脑电信号(EEG)分类识别是脑-机接口(BCI)研究领域的重要问题。本文通过经验模式分解(EMD)将EEG分解为一系列内蕴模式函数(IMF),并对重要IMF的瞬时幅度提取AR模型参数,同时对所有的IMF进行Hilbert变换(HT)得到Hilbert谱,进而... 对运动想象脑电信号(EEG)分类识别是脑-机接口(BCI)研究领域的重要问题。本文通过经验模式分解(EMD)将EEG分解为一系列内蕴模式函数(IMF),并对重要IMF的瞬时幅度提取AR模型参数,同时对所有的IMF进行Hilbert变换(HT)得到Hilbert谱,进而求得瞬时能量(IE)。将得到的AR参数和IE,结合时域均值和中值绝对偏差估计(MAD),组成初始特征,然后利用经遗传算法(GA)优化的支持向量机(SVM)进行分类,得到识别结果。对2008年BCI CompetitionⅣDataset 1中想象左手和脚运动的两组数据进行识别,在仅仅使用少数通道的情况下,识别正确率分别达到84.7%和85.8%,初步验证了该方法的有效性。 展开更多
关键词 Hilbert-Huang变换(HHT) 遗传算法(GA) 支持向量机(SVM) 运动想象 分类识别
暂未订购 下载PDF
微电网HHT谐波检测与时频分析方法 认领 引用 被引量:13
9
作者 关维国 姚清志 鲁宝春 《计算机工程与应用》 CSCD 北大核心 2015年第20期198-202,212,共5页
为解决微电网谐波、突变等复杂非平稳信号的精确检测问题,提出一种基于Hilbert-Huang变换(HHT)的微电网谐波检测与时频分析方法。该方法采用保形分段三次埃尔米特插值法拟合极值点曲线,对谐波信号进行经验模态分解(EMD),得到有限个固有... 为解决微电网谐波、突变等复杂非平稳信号的精确检测问题,提出一种基于Hilbert-Huang变换(HHT)的微电网谐波检测与时频分析方法。该方法采用保形分段三次埃尔米特插值法拟合极值点曲线,对谐波信号进行经验模态分解(EMD),得到有限个固有模态分量(IMF)并进行Hilbert变换,最终计算各个IMF分量的瞬时频率和瞬时幅值,实现微电网谐波等非平稳电能信号的时频特性精确检测。仿真结果表明,该方法能够快速、准确地获取谐波信号频率成分、幅度及电压突变时刻。相对于FFT变换及传统HHT方法具有较高的精度和时域区分特性,可满足微电网谐波微机检测的工程应用需求。 展开更多
关键词 微电网 谐波检测 希尔伯特-黄变换(HHT) 经验模态分解 瞬时频率 Hilbert-Huang Transform(HHT)
暂未订购 下载PDF
基于HHT和CSSD的多域融合自适应脑电特征提取方法 认领 引用 被引量:36
10
作者 李明爱 崔燕 +1 位作者 杨金福 郝冬梅 《电子学报》 EI CAS CSCD 北大核心 2013年第12期2479-2486,共8页
为改善运动想象脑电信号特征提取的自适应性和实时性,提出一种基于希尔伯特-黄变换(HHT)与共空域子空间分解算法(CSSD)的特征提取方法(HCSSD).在对脑电信号进行预处理的基础上,定义一种相对距离准则优选脑电极组合;计算脑电的Hilbert瞬... 为改善运动想象脑电信号特征提取的自适应性和实时性,提出一种基于希尔伯特-黄变换(HHT)与共空域子空间分解算法(CSSD)的特征提取方法(HCSSD).在对脑电信号进行预处理的基础上,定义一种相对距离准则优选脑电极组合;计算脑电的Hilbert瞬时能量谱和边际能量谱,以获取脑电的时-频特征,并基于CSSD提取其空域特征,采用串行特征融合策略得到脑电的时-频-空特征;设计学习矢量量化神经网络分类器,实现脑电数据分类.在训练集与测试集间隔一周且减少导联数量的情况下,基于HCSSD对左手小指和舌头的运动想象ECoG脑电数据的平均识别率为92%.实验结果表明:HCSSD在增强特征提取方法的自适应性、改善实时性的同时,提高了脑电信号识别率,为便携式BCI系统在康复领域的应用创造了条件. 展开更多
关键词 脑机接口 运动想象 希尔伯特-黄变换 共空域子空间分解 特征融合 自适应 brain-computer interface (BCI) motor imagery (MI) hilbert-huang transform (HHT) common spatial sub-space decomposition (CSSD
暂未订购 下载PDF
基于HHT与滤波算法的风电波动平抑策略研究 认领 引用 被引量:12
11
作者 徐玉韬 谈竹奎 +1 位作者 肖永 吕黔苏 《电气传动》 北大核心 2019年第2期56-60,共5页
由于一阶低通滤波算法在实际工程中具有较好的实用性,因此用其进行风电功率波动的平抑。首先,应用希尔伯特黄变换(HHT)获取风电的主频率,以此求取初始滤波时间常数。然后,滤波时间常数最小作为目标,以风电并网波动率等为约束,动态调整... 由于一阶低通滤波算法在实际工程中具有较好的实用性,因此用其进行风电功率波动的平抑。首先,应用希尔伯特黄变换(HHT)获取风电的主频率,以此求取初始滤波时间常数。然后,滤波时间常数最小作为目标,以风电并网波动率等为约束,动态调整滤波时间步长,从而实现对风电波动的平抑。再者,以混合储能经济性最优为目标,同时兼顾充放电功率和SOC等约束,实现储能总载荷在蓄电池和超级电容器之间的分配。最后,通过算例验证了控制策略的有效性。 展开更多
关键词 风电波动平抑 一阶低通滤波算法 希尔伯特黄变换 滤波时间常数 储能经济性
暂未订购 下载PDF
基于HHT和IPSO算法优化RBF神经网络的滚刀磨损状态识别方法 认领 引用 被引量:5
12
作者 李国龙 李彪 +2 位作者 蒋林 柯昊 付扬 《吉林大学学报(工学版)》 EI CAS CSCD 北大核心 2020年第6期1998-2009,共12页
针对滚齿加工工艺复杂滚刀磨损状态难以准确识别的难题,提出了一种结合希尔伯特黄变换(HHT)和改进粒子群算法优化的RBF神经网络(IPSO-RBF)识别滚刀磨损状态方法。首先,采集在全生命周期下滚刀加工的主轴Z向振动信号,并用小波阈值方法去... 针对滚齿加工工艺复杂滚刀磨损状态难以准确识别的难题,提出了一种结合希尔伯特黄变换(HHT)和改进粒子群算法优化的RBF神经网络(IPSO-RBF)识别滚刀磨损状态方法。首先,采集在全生命周期下滚刀加工的主轴Z向振动信号,并用小波阈值方法去除其高频噪声成分。其次,采用经验模态分解(EMD)将去噪后信号分解成若干个本征模态函数(IMF)分量,计算并筛选IMF分量的能量值及其边际谱能量值,构造滚刀磨损状态特征向量。然后,改进标准粒子群算法,再用其优化RBF神经网络。最后,将特征向量输入优化后的RBF神经网络进行训练,实现滚刀磨损状态的自动识别。实验结果表明,该方法能够有效识别滚刀的磨损状态,识别率可达98.75%。 展开更多
关键词 滚刀磨损状态 希尔伯特黄变换 小波阈值去噪 改进粒子群算法 RBF神经网络
10 kV配电网电磁式电压互感器谐振特性及识别方法的研究 认领 引用
13
作者 李志彪 宋建成 +1 位作者 程胤璋 郑俊琪 《高压电器》 CAS CSCD 北大核心 2026年第6期130-137,共8页
在小电流接地系统中,当发生不正常运行状态时,配电线路的分布电容会与电压互感器(potential transformer,PT)一次侧的绕组电感发生谐振,从而产生谐振过电压,严重时会烧毁PT,甚至发生爆炸,严重威胁人身和设备安全。文中以山西某110 kV变... 在小电流接地系统中,当发生不正常运行状态时,配电线路的分布电容会与电压互感器(potential transformer,PT)一次侧的绕组电感发生谐振,从而产生谐振过电压,严重时会烧毁PT,甚至发生爆炸,严重威胁人身和设备安全。文中以山西某110 kV变电站10 kV配电网为研究对象,在PSCAD/EMTDC中建立了仿真模型,分析了线路分布电容(线路长度)、PT容量对谐振特性的影响规律,对于不同类型的谐振提出了VMD-HHT-WOA-SVM识别算法。研究发现,线路长度及PT容量的大小对配电网铁磁谐振均有影响,在实际工况中,由于线路参数与PT励磁特性的影响,高频谐振基本不会发生;基于VMD-HHT-WOA-SVM的PT谐振类别识别方法准确率可达95%,能有效地识别谐振类型与谐振发生时刻。 展开更多
关键词 电压互感器 铁磁谐振 谐振特性 VMD-HHT-WOA-SVM谐振识别算法
暂未订购 下载PDF
基于Hilbert-Huang变换的语音信号分离 认领 引用 被引量:3
14
作者 张朝柱 张健沛 孙晓东 《计算机应用》 北大核心 2009年第1期227-229,255,共3页
针对短时傅里叶变换不能正确得到非平稳信号的能量频率分布问题,提出了一种基于Hilbert-Huang变换的单信道语音信号分离的算法。该算法首先对分解得到的各内蕴模式函数分量(IMF)进行Hilbert变换,得到混合信号时频面上的Hilbert谱,然后... 针对短时傅里叶变换不能正确得到非平稳信号的能量频率分布问题,提出了一种基于Hilbert-Huang变换的单信道语音信号分离的算法。该算法首先对分解得到的各内蕴模式函数分量(IMF)进行Hilbert变换,得到混合信号时频面上的Hilbert谱,然后对混合信号的Hilbert谱运用独立子空间分析的方法得出代表各个独立源信号的子空间,并对其求逆变换,从而恢复出各个源信号。通过仿真实验验证了此算法的正确性和有效性,且与短时傅里叶变换时频分析法相比较,其分离性能明显得到改善,显示了Hilbert-Huang变换在处理非平稳信号的优越性。 展开更多
关键词 Hilbert—Huang变换 内在模式分解 独立子空间分析 C-均值算法
暂未订购 下载PDF
基于改进HHT算法的谐波信号分析方法 认领 引用 被引量:5
15
作者 徐健 张禹 吴飞飞 《电子测量技术》 2018年第8期30-34,共5页
电能被广泛运用在动力、冶金、照明、通信等各个领域,电力系统中存在大量的非稳态信号,而希尔伯特-黄变换(HHT)算法非常适合对非稳态信号进行时频分析。介绍了HHT的基本原理,并针对其存在的端点效应、模态混叠等问题提出了一种改进HH... 电能被广泛运用在动力、冶金、照明、通信等各个领域,电力系统中存在大量的非稳态信号,而希尔伯特-黄变换(HHT)算法非常适合对非稳态信号进行时频分析。介绍了HHT的基本原理,并针对其存在的端点效应、模态混叠等问题提出了一种改进HHT算法,其基本原理是采用集合经验模态分解(EEMD)将非线性、非平稳的原始信号分解成若干固有模态分量(IMF),再对每个IMF分别进行Hilbert变换获得相应的瞬时特征量,从而建立短时谐波模型。EEMD在信号分解的过程中通过增加白噪声以达到减少频谱混叠的目的,测试值增多必然会使误差减小,精度提高,在一定程度上弥补了经验模态分解(EMD)的不足,并通过实验仿真验证了EEMD分解的可行性和高效性。 展开更多
关键词 HHT算法 Hilber1t变换 集合经验模态分解(EEMD) 谐波模型
暂未订购 下载PDF
HHT方法在轴承故障诊断中的应用 认领 引用 被引量:4
16
作者 耶晓东 《陕西理工学院学报(自然科学版)》 2012年第4期9-13,共5页
为研究滚动轴承故障问题,将HHT(Hilbert-Huang transform)分析方法应用于轴承信号故障的提取。用HHT对复合信号进行了仿真分析,表明此方法分析信号的有效性。将HHT方法应用于轴承内外圈的故障诊断,结果表明,所求出的轴承故障的信息特征... 为研究滚动轴承故障问题,将HHT(Hilbert-Huang transform)分析方法应用于轴承信号故障的提取。用HHT对复合信号进行了仿真分析,表明此方法分析信号的有效性。将HHT方法应用于轴承内外圈的故障诊断,结果表明,所求出的轴承故障的信息特征与理论计算吻合,表明了HHT方法能够有效的提取轴承故障的特征信息,提高轴承故障诊断率。这为类似机械零部件的故障诊断提供了参考。 展开更多
关键词 HHT(Hilbert-Huang transform) 故障诊断 轴承
暂未订购 下载PDF
Improved HHT and its application in narrowband radar imaging for precession cone-shaped targets 认领 引用 被引量:2
17
作者 Shen Zhao Jie Niu +1 位作者 Xiang Li Chunjie Qiao 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2014年第6期977-986,共10页
Imaging the spatial precession cone-shaped targets with narrowband radar is a new technical approach in mid-course recognition problem. However, most existing time-frequency methods still have some inevitable deficien... Imaging the spatial precession cone-shaped targets with narrowband radar is a new technical approach in mid-course recognition problem. However, most existing time-frequency methods still have some inevitable deficiencies for extracting microDoppler information in practical applications, which leads to blurring of the image. A new narrowband radar imaging algorithm for the precession cone-shaped targets is proposed. The instantaneous frequency of each scattering point is gained by using the improved Hilbert-Huang transform, then the positions of scattering points in the parameter domain are reconstructed. Numerical simulation and experiment results confirm the effectiveness and high precision of the proposed algorithm. 展开更多
关键词 improved Hilbert-Huang transformHHT instanta-neous frequency narrowband radar imaging precession cone-shaped targets
暂未订购 下载PDF
基于HHT变换和FOA_LSSVM的电缆故障诊断 认领 引用 被引量:5
18
作者 苏立 《计算机与现代化》 2017年第9期96-101,105,共6页
针对现有的地下电缆故障诊断方法存在准确率不高、误差较大的缺点,提出一种基于HHT变换和FOA_LSSVM的地下电缆故障诊断方法。针对地下电缆故障信号,通过HHT变换提取地下电缆故障信号的特征分量,将提取的特征分量和地下电缆故障类型作为F... 针对现有的地下电缆故障诊断方法存在准确率不高、误差较大的缺点,提出一种基于HHT变换和FOA_LSSVM的地下电缆故障诊断方法。针对地下电缆故障信号,通过HHT变换提取地下电缆故障信号的特征分量,将提取的特征分量和地下电缆故障类型作为FOA_LSSVM的输入和输出,实现地下电缆故障类型的识别。以150组地下电缆故障数据为实验对象,结果表明,FOA_LSSVM比GA_LSSVM,PSO_LSSVM和DE_LSSVM具有更高的准确率,更适合地下电缆故障的诊断和识别。 展开更多
关键词 果蝇优化算法 最小二乘支持向量机 电缆故障 HHT变换
暂未订购 下载PDF
基于HHT方法的三水站月均流量序列的多时间尺度分析 认领 引用 被引量:1
19
作者 钱海强 《广东水利水电》 2011年第5期32-33,36,共2页
应用基于经验模态分解(EMD)的Hilbert-Huang Transform(HHT)方法对珠江三角洲网河区顶端三水水文站1960~2009年的月均流量序列进行多时间尺度分析,结果表明:网河区顶端三水站的月均流量具有明显的年内(0.27~0.58a)、年际(平均周期1.1... 应用基于经验模态分解(EMD)的Hilbert-Huang Transform(HHT)方法对珠江三角洲网河区顶端三水水文站1960~2009年的月均流量序列进行多时间尺度分析,结果表明:网河区顶端三水站的月均流量具有明显的年内(0.27~0.58a)、年际(平均周期1.16a)、多年(2.38~5.00a)和年代际(10.00~25.00a)周期变化,并且以年内的周期波动最为重要;2010~2015年三水站来水量呈上升趋势。 展开更多
关键词 三水站 Hilbert-Huang Transform(HHT)方法 月均流量
暂未订购 下载PDF
基于小波去噪与HHT的隔膜泵主轴故障诊断研究 认领 引用 被引量:1
20
作者 印嘉 《装备制造技术》 2015年第5期138-140,共3页
往复式活塞隔膜泵的主轴的运行状况的好坏,直接影响着隔膜泵的正常运行,乃至整个管道输送系统的有效运行。提出一种基于小波去噪与HHT相结合的往复式活塞隔膜泵主轴故障诊断方法。先采用小波变换对原始振动信号进行去噪,再对去噪后的振... 往复式活塞隔膜泵的主轴的运行状况的好坏,直接影响着隔膜泵的正常运行,乃至整个管道输送系统的有效运行。提出一种基于小波去噪与HHT相结合的往复式活塞隔膜泵主轴故障诊断方法。先采用小波变换对原始振动信号进行去噪,再对去噪后的振动信号进行HHT处理,可以得到HHT边际谱,最后通过分析HHT边际谱,实现了对设备故障有效的诊断和研究。实验表明,通过基于小波去噪与HHT的方法对往复式隔膜泵主轴的故障诊断是有效的和可行的。 展开更多
关键词 往复式隔膜泵 主轴 小波去噪 Hilbert-Huang Transform(HHT) 边际谱 故障诊断