期刊文献+
共找到318篇文章
< 1 2 16 >
每页显示 20 50 100
Correction:Fault Identification in Renewable Energy Transmission Lines Using Wavelet Packet Decomposition and Voltage Waveform Analysis 认领 引用
1
作者 Huajie Zhang Xiaopeng Li +2 位作者 Hanlin Xiao Lifeng Xing Wenyue Zhou 《Energy Engineering》 EI 2026年第8期374-374,共1页
Fault Identification in Renewable Energy Transmission Lines Using Wavelet Packet Decomposition and Voltage Waveform Analysis,vol.123,no.3,pp.20,2026.http://gffzzd3cc09b8251d45dfsv9cufc0owfpf69xx.ffgz.tsg.suse.edu.cn/10.32604/ee.2026.071768.Following publication of the... Fault Identification in Renewable Energy Transmission Lines Using Wavelet Packet Decomposition and Voltage Waveform Analysis,vol.123,no.3,pp.20,2026.http://gffzzd3cc09b8251d45dfsv9cufc0owfpf69xx.ffgz.tsg.suse.edu.cn/10.32604/ee.2026.071768.Following publication of the article,a request was received to correct the institutional affiliation of the authors.The request was supported by relevant documentation and approved by all authors. 展开更多
关键词 renewable energy transmission lines wavelet packet decomposition correct institutional affiliation transmission lines voltage waveform analysisvol no pp https doiorg ee following renewable energy fault identification
暂未订购 下载PDF
Enhanced sparse RCNN for transmission line bolt defect detection via text-to-image data augmentation and quality filtering 认领 引用
2
作者 Chen Zhenyu Yan Huaguang +2 位作者 Du Jianguang Xue Meng Zhao Shuai 《High Technology Letters》 EI CAS 2026年第1期11-20,共10页
To address the issue of inconsistent image quality and data scarcity in bolt defect detection for transmission lines,this paper proposes an improved sparse region-based convolutional neural network(RCNN) based detecti... To address the issue of inconsistent image quality and data scarcity in bolt defect detection for transmission lines,this paper proposes an improved sparse region-based convolutional neural network(RCNN) based detection framework integrating image quality evaluation and text-to-image data augmentation.First,a HyperNetwork-based image quality assessment module is introduced to filter low-quality inspection images in terms of clarity and structural integrity,resulting in a high-quality training dataset.Second,a text-to-image diffusion model is utilized for sample augmentation.By designing text prompts that describe various bolt defect types under diverse lighting and viewing conditions,the model automatically generates realistic synthetic samples.The generated images are further filtered using a combination of quality and perceptual similarity metrics to ensure consistency with the real data distribution.Building upon the sparse RCNN baseline,a dynamic label assignment mechanism and a random decision path detection head are incorporated to enhance bounding box matching and prediction accuracy.Experimental results demonstrate that the proposed method significantly improves detection accuracy(mAP@0.5) over the original sparse RCNN while maintaining low computational cost,enabling more efficient and intelligent inspection of transmission line components. 展开更多
关键词 sparse region-based convolutional neural network HyperNetwork image quality assessment text-to-image generation data augmentation bolt defect detection transmission line inspection
暂未订购 下载PDF
Review of Deep Learning-Based Intelligent Inspection Research for Transmission Lines 认领 引用
3
作者 Jingjing Liu Chuanyang Liu 《Computers, Materials & Continua》 SCIE EI 2026年第5期155-198,共44页
Intelligent inspection of transmission lines enables efficient automated fault detection by integrating artificial intelligence,robotics,and other related technologies.It plays a key role in ensuring power grid safety... Intelligent inspection of transmission lines enables efficient automated fault detection by integrating artificial intelligence,robotics,and other related technologies.It plays a key role in ensuring power grid safety,reducing operation and maintenance costs,driving the digital transformation of the power industry,and facilitating the achievement of the dual-carbon goals.This review focuses on vision-based power line inspection,with deep learning as the core perspective to systematically analyze the latest research advancements in this field.Firstly,at the technical foundation level,it elaborates on deep learning algorithms for intelligent transmission line inspection based on image perception,covering object detection algorithms,semantic segmentation algorithms,and other relevant methodologies.Secondly,in application practice,it summarizes deep learning-based intelligent inspection applications across six dimensions—including detection of power insulators and their defects,transmission tower detection,power line feature extraction,metal fitting and defect detection,thermal fault diagnosis of power components,and safety hazard detection in power scenarios,and further lists relevant public datasets.Finally,in response to current challenges,it identifies five key future research directions,such as the deep integration of multiple learning paradigms,multi-modal data fusion,collaborative application of large and small models,cloud-edge-end collaborative integration,and multi-agent cluster control.This paper reviews and analyzes numerous deep learning-based intelligent detectionmethods for aerial images,comprehensively explores the application of deep learning in Unmanned Aerial Vehicle(UAV)inspection scenarios,and thus provides valuable theoretical and practical references for scholars engaged in smart grid automated inspection research. 展开更多
关键词 Intelligent inspection transmission lines deep learning defect detection
暂未订购 下载PDF
A Non-Unit Protection Based on Propagation of Fault Traveling Wave for Transmission Line Connected to Wind Power Plant 认领 引用
4
作者 Hao Wang Wenyue Zhou Yiping Luo 《Energy Engineering》 EI 2025年第9期3737-3752,共16页
Currently,renewable energy has been broadly implemented across diverse sectors,particularly evidenced by its substantially higher integration levels in power systems.Thelarge-scale integration of renewable energy reso... Currently,renewable energy has been broadly implemented across diverse sectors,particularly evidenced by its substantially higher integration levels in power systems.Thelarge-scale integration of renewable energy resources introduces distinct fault characteristics into power grids,potentially rendering traditional line protection schemes inadequate for transmission lines interfacing with these sources.Therefore,it is imperative to study line protection methods unaffected by the integration of renewable energy resources.After analyzing the propagation process of the fault traveling wave along the transmission line,a non-unit protection based on traveling wave distancemeasurement is proposed.The core principle of the proposedmethod relies onmeasuring the temporal interval ΔT between detections of the first and second fault backward traveling waves at the measurement point.The Teager energy operator(TEO),which demonstrates advantages in highlighting stepmutation characteristics,was employed to extract ΔT by processing the fault backward traveling wave signal detected at the measurement point.To evaluate the efficacy of the proposed protection method,various fault scenarios were simulated in the established PSCAD/EMTDC simulation system.Validation results confirm that the proposed non-unit protection can provide full-line protection coverage,enabling fast and reliable discrimination of internal and external faults with inherent immunity to renewable energy penetration. 展开更多
关键词 Teager energy operator traveling wave protection for transmission line wind power
暂未订购 下载PDF
GFRF R-CNN:Object Detection Algorithm for Transmission Lines 认领 引用 被引量:2
5
作者 Xunguang Yan Wenrui Wang +3 位作者 Fanglin Lu Hongyong Fan Bo Wu Jianfeng Yu 《Computers, Materials & Continua》 SCIE EI 2025年第1期1439-1458,共20页
To maintain the reliability of power systems,routine inspections using drones equipped with advanced object detection algorithms are essential for preempting power-related issues.The increasing resolution of drone-cap... To maintain the reliability of power systems,routine inspections using drones equipped with advanced object detection algorithms are essential for preempting power-related issues.The increasing resolution of drone-captured images has posed a challenge for traditional target detection methods,especially in identifying small objects in high-resolution images.This study presents an enhanced object detection algorithm based on the Faster Regionbased Convolutional Neural Network(Faster R-CNN)framework,specifically tailored for detecting small-scale electrical components like insulators,shock hammers,and screws in transmission line.The algorithm features an improved backbone network for Faster R-CNN,which significantly boosts the feature extraction network’s ability to detect fine details.The Region Proposal Network is optimized using a method of guided feature refinement(GFR),which achieves a balance between accuracy and speed.The incorporation of Generalized Intersection over Union(GIOU)and Region of Interest(ROI)Align further refines themodel’s accuracy.Experimental results demonstrate a notable improvement in mean Average Precision,reaching 89.3%,an 11.1%increase compared to the standard Faster R-CNN.This highlights the effectiveness of the proposed algorithm in identifying electrical components in high-resolution aerial images. 展开更多
关键词 Faster R-CNN transmission line object detection GIOU GFR
暂未订购 下载PDF
Vibration suppression analysis of iced transmission lines under axial time-delay velocity feedback strategy 认领 引用
6
作者 Maoming Hu Guangyun Min +3 位作者 Wanyu Bao Bowen Tian Shuguang Yang Mengqi Cai 《Theoretical & Applied Mechanics Letters》 EI CAS CSCD 2025年第1期69-86,共18页
To ensure the safety of power energy transmission channel and mitigate the harm caused by galloping of iced transmission lines,the axial time-delay velocity feedback strategy is adopted to suppress the galloping.The p... To ensure the safety of power energy transmission channel and mitigate the harm caused by galloping of iced transmission lines,the axial time-delay velocity feedback strategy is adopted to suppress the galloping.The par-tial differential equation of galloping with axial time-delay velocity feedback strategy is established based on the variational principle for Hamiltonian.Then,the partial differential equation of galloping is transformed into or-dinary differential equation based on normalization and the Galerkin method.The primary amplitude-frequency response equation,the first-order steady-state approximate solution,and the harmonic amplitude-frequency re-sponse equation are derived by the multiscale method.The impact of different parameters such as time-delay value,control coefficient,and amplitude of external excitation on the galloping response are analyzed.The am-plitude under the primary resonance exhibits periodicity as time-delay value varies.The amplitude diminishes with increased control coefficient and increases with external excitation.Comprehensive consideration of vari-ous influences of parameters on vibration characteristics is crucial when employing the axial time-delay velocity feedback strategy to suppress galloping.Therefore,to achieve the best vibration suppression effect,it is crucial to adjust the time-delay parameter for modifying the range and amplitude of the resonance zone.The conclusions obtained by this study are expected to advance the refinement of active control techniques for iced transmission lines,and may provide valuable insights for practical engineering applications. 展开更多
关键词 Iced transmission lines Galloping characteristics Axial time-delay velocity feedback strategy Primary resonance Harmonic resonance
暂未订购 下载PDF
MAID:making accurate transmission line icing detector by enhancing inaccurate dataset 认领 引用
7
作者 SUN Wei WANG Yu +3 位作者 GAO Bo ZHANG Shujuan WANG Xiaojin XING Lu 《Optoelectronics Letters》 EI 2025年第10期606-611,共6页
Power transmission lines are a critical component of the entire power system,and ice accretion incidents caused by various types of power systems can result in immeasurable harm.Currently,network models used for ice d... Power transmission lines are a critical component of the entire power system,and ice accretion incidents caused by various types of power systems can result in immeasurable harm.Currently,network models used for ice detection on power transmission lines require a substantial amount of sample data to support their training,and their drawback is that detection accuracy is significantly affected by the inaccurate annotation among training dataset.Therefore,we propose a transformer-based detection model,structured into two stages to collectively address the impact of inaccurate datasets on model training.In the first stage,a spatial similarity enhancement(SSE)module is designed to leverage spatial information to enhance the construction of the detection framework,thereby improving the accuracy of the detector.In the second stage,a target similarity enhancement(TSE)module is introduced to enhance object-related features,reducing the impact of inaccurate data on model training,thereby expanding global correlation.Additionally,by incorporating a multi-head adaptive attention window(MAAW),spatial information is combined with category information to achieve information interaction.Simultaneously,a quasi-wavelet structure,compatible with deep learning,is employed to highlight subtle features at different scales.Experimental results indicate that the proposed model in this paper outperforms existing mainstream detection models,demonstrating superior performance and stability. 展开更多
关键词 power transmission lines ice detection ice accretion sample data spatial similarity enhancement power systemand transformer based model power systems
暂未订购 下载PDF
Transmission line fault-cause identification method for large-scale new energy grid connection scenarios 认领 引用 被引量:11
8
作者 Hanqing Liang Xiaonan Han +3 位作者 Haoyang Yu Fan Li Zhongjian Liu Kexin Zhang 《Global Energy Interconnection》 EI CSCD 2022年第4期362-374,共13页
The accurate fault-cause identification for overhead transmission lines supports the operation and maintenance personnel in formulating targeted maintenance strategies and shortening the time of inspecting faulty line... The accurate fault-cause identification for overhead transmission lines supports the operation and maintenance personnel in formulating targeted maintenance strategies and shortening the time of inspecting faulty lines.With the goal of achieving“carbon peak and carbon neutrality”,the schemes for clean energy generation have rapidly developed.Moreover,new energy-consuming equipment has been widely connected to the power grid,and the operating characteristics of the power system have significantly changed.Consequently,these have impacted traditional fault identification methods.Based on the time-frequency characteristics of the fault waveform,new energy-related parameters,and deep learning model,this study proposes a fault identification method suitable for scenarios where a high proportion of new energy is connected to the power grid.Ten parameters related to the causes of transmission line fault and new energy connection scenarios are selected as model characteristic parameters.Further,a fault identification model based on adaptive deep belief networks was constructed,and its effect was verified by field data. 展开更多
关键词 Fault-cause identification Transmission lines Fault waveform Large-scale new energy Fault cause
暂未订购 下载PDF
Investigation of an X-band magnetically insulated transmission line oscillator 认领 引用 被引量:11
9
作者 樊玉伟 钟辉煌 +6 位作者 李志强 舒挺 杨汉武 杨建华 王勇 罗玲 赵延宋 《Chinese Physics B》 SCIE EI CAS 2008年第5期1804-1808,共5页
An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulat... An X-band magnetically insulated transmission line oscillator (MILO) is designed and investigated numerically and experimentally for the first time. The X-band MILO is optimized in detail with KARAT code. In simulation, the X-band MILO, driven by a 720 kV, 53 kA electron beam, comes to a nonlinear steady state in 4.0 ns. High-power microwaves (HPM) of TEM mode is generated with an average power of 4.1 GW, a frequency of 9.3 GHz, and power conversion efficiency of 10.870 in durations of 0-40 ns. The device is fabricated according to the simulation results. In experiments, when the voltage is 400 kV and the current is 50 kA, the radiated microwave power reaches about 110 MW and the dominating frequency is 9.7GHz. Because the surfaces of the cathode end and the beam dump are destroyed, the diode voltage cannot increase continuously. However, when the diode voltage is 400 kV, the average power output is obtained to be 700 MW in simulation. The impedance of the device is clearly smaller than the simulation prediction. Moreover, the duration of the microwave pulse is obviously shorter than that of the current pulse. The experimental results are greatly different from the simulation predictions. The preliminary analyses show that the generations of the anode plasma, the cathode flare and the anode flare are the essential cause for the remarkable deviation of the experimental results from the simulation predictions. 展开更多
关键词 magnetically insulated transmission line oscillator (MILO) high-power microwaves(HPM) pulse shortening
暂未订购 下载PDF
Statistics and Analysis of Lightning Flashovers of Transmission Lines During 2000-2007 认领 引用 被引量:16
10
作者 LI Xiao-lan CHEN Jia-hong +1 位作者 GU Shan-qiang TONG Xue-fang 《高电压技术》 EI CAS 北大核心 2009年第3期705-710,共6页
Lightning stroke is one of the important causes of the accidents that occur on transmission lines.With the development of power system,the proportion of outages on transmission lines because of lightning stroke also i... Lightning stroke is one of the important causes of the accidents that occur on transmission lines.With the development of power system,the proportion of outages on transmission lines because of lightning stroke also increases.And according to the lightning accidents results,the lightning stroke characteristics is related to the time factors tightly.In order to analyze the correlativity between the lightning flashover amount and the time factors,about 425 times lightning flashover on 187 lines in 10 power supply companies of 220 kV and 500 kV transmission lines during 2000-2007 are investigated in this paper.The correlativity between the lightning flashover amount and the time factors is analyzed.According to the lightning stroke accidents investigation records,the lightning flashover amount of transmission line increases from the year of 2000 to 2007.In each year lightning flashovers mostly happen in the month of June,July and August.Similarly in each day the flashover amount also varies with the time of day obviously.These lightning flashovers mainly occur during 14:00-21:00 in the afternoon.The analysis results in this paper have a good agreement with the meteorological observations and lightning detection data of lightning location system(LLS).And these results provide good reference for the lightning protection work in power system. 展开更多
关键词 lightning flashover lightning stroke transmission line lightning detection lightning accidents classified statistics lightning location system
暂未订购 下载PDF
Fiber Bragg grating monitors for thermal and stress of the composite insulators in transmission lines 认领 引用 被引量:6
11
作者 Heming Deng Wei Cai +3 位作者 You Song Jinsong Liu Christopher Redman Qiandong Zhuang 《Global Energy Interconnection》 2018年第3期382-390,共9页
Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bra... Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bragg grating(FBG) as the monitors to parameters correlated with thermal and stress of the composite insulators in transmission lines at working status. Firstly, monitoring points are found out by the mechanical test on composite insulator samples. Secondly, based on the monitoring theory, this paper introduces the feasibility design frame of the composite insulator with FBG implanted in the rod and the online monitor system. At last, it describes applications of this monitor system in the field of transmission lines. 展开更多
关键词 Thermal monitoring Stress monitoring Composite insulators Transmission lines Fiber Bragg grating monitors
暂未订购 下载PDF
High Precision Ultrasonic Guided Wave Technique for Inspection of Power Transmission Line 认领 引用 被引量:4
12
作者 CHENG Jun QIU Jinhao +3 位作者 JI Hongli WANG Enrong TAKAGI Toshiyuki UCHIMOTO Tetsuya 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第1期170-179,共10页
Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave pr... Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line. 展开更多
关键词 ultrasonic guided wave inspection power transmission line piezoelectric transducer defect positioning wavelet transform
暂未订购 下载PDF
Time-domain analytic solutions of two-wire transmission line excited by a plane-wave field 认领 引用 被引量:9
13
作者 倪谷炎 颜力 袁乃昌 《Chinese Physics B》 SCIE EI CAS 2008年第10期3629-3634,共6页
This paper reports that an analytic method is used to calculate the load responses of the two-wire transmission line excited by a plane-wave directly in the time domain. By the frequency-domain Baum Liu-Tesehe (BLT)... This paper reports that an analytic method is used to calculate the load responses of the two-wire transmission line excited by a plane-wave directly in the time domain. By the frequency-domain Baum Liu-Tesehe (BLT) equation, the time-domain analytic solutions are obtained and expressed in an infinite geometric series. Moreover, it is shown that there exist only finite nonzero terms in the infinite geometric series if the time variate is at a finite interval. In other word, the time-domain analytic solutions are expanded in a finite geometric series indeed if the time variate is at a finite interval. The computed results are subsequently compared with transient responses obtained by using the frequency-domain BLT equation via a fast Fourier transform, and the agreement is excellent. 展开更多
关键词 transmission line analytic solution BLT equation coupling formulation.
暂未订购 下载PDF
A k-band broadband monolithic distributed frequency multiplier based on nonlinear transmission line 认领 引用 被引量:4
14
作者 黄杰 董军荣 +3 位作者 杨浩 张海英 田超 郭天义 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第6期145-149,共5页
A fabrication technology of GaAs planar Schottky varactor diode (PSVD) is successfully developed and used to design and manufacture CaAs-based monolithic frequency multiplication based on 23-section nonlinear transm... A fabrication technology of GaAs planar Schottky varactor diode (PSVD) is successfully developed and used to design and manufacture CaAs-based monolithic frequency multiplication based on 23-section nonlinear transmission lines (NLTLs) consisting of a coplanar waveguide transmission line and periodically distributed PSVDs. The throughout design and optimization procedure of 23-section monolithic NLTLs for frequency multiplication in the k-band range is based on a large signal equivalent model of PSVD extracted from small-signal S-parameter measurements. This paper reports that the distributed SPVD exhibits a capacitance ratio of 5.4, a normalized capacitance of 0.86 fF/μm2 and a breakdown voltage in excess of 22 V. The integrated 23-section NLTLs fed by 20-dBm input power demonstrates a 26-GHz peak second harmonic output power of 14-dBm with 25.3% conversion efficiency in the second harmonic output frequency range of 6 GHz-26 GHz. 展开更多
关键词 nonlinear transmission line frequency multiplication harmonic generation planar Schottky varactor diode
暂未订购 下载PDF
Modern Travelling Wave Based Fault Location Techniques for HVDC Transmission Lines 认领 引用 被引量:10
15
作者 陈平 徐丙垠 +1 位作者 李京 葛耀中 《Transactions of Tianjin University》 EI CAS 2008年第2期139-143,共5页
The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Bas... The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation. 展开更多
关键词 fault location global positioning system HVDC transmission lines repeaters
暂未订购 下载PDF
Magnetically insulated transmission line oscillator oscillated in a modified HEM11 mode 认领 引用 被引量:5
16
作者 王冬 陈代兵 +1 位作者 秦奋 范植开 《Chinese Physics B》 SCIE EI CAS 2009年第10期4281-4286,共6页
This paper puts forward a novel magnetically insulated transmission line oscillator (MILO) for the first time which takes a modified HEM11 mode as its main interaction mode. The excitation of the oscillation mode is... This paper puts forward a novel magnetically insulated transmission line oscillator (MILO) for the first time which takes a modified HEM11 mode as its main interaction mode. The excitation of the oscillation mode is made possible by carefully adjusting the arrangements of each resonant cavity in a two-dimensional (2-D) slow wave structure. The high frequency characteristics are analyzed and a PIC simulation is carried out; the detailed results are discussed to get a better understanding of this new MILO. Employing an electron beam of about 441 kV and 39.7 kA, it finds that the modified HEM11 mode MILO generates a high power microwave output of about 1.47 GW at 1.45 GHz. The power conversion efficiency is about 8.4% and the generated microwave is in a TEll-like circularly polarized mode; its polarization direction is decided by the rotation direction of the SWS. 展开更多
关键词 high power microwave magnetically insulated transmission line oscillator asymmetricmode HEM11 mode circularly polarized mode
暂未订购 下载PDF
Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level 认领 引用 被引量:4
17
作者 吴撼宇 曾正中 +1 位作者 王亮平 郭宁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第6期625-628,共4页
A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/... A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL. 展开更多
关键词 magnetically insulated transmission line current loss current density ion
暂未订购 下载PDF
On the formation and wind enhancement mechanisms of a Mongolian cyclone that caused a transmission line galloping trip in Gansu province 认领 引用 被引量:4
18
作者 Shuanglong Jin Shuanglei Feng +4 位作者 Xiaolin Liu Bo Wang Zongpeng Song Wei Cui Cong Wang 《Atmospheric and Oceanic Science Letters》 CSCD 2021年第2期28-34,共7页
Influenced by strong winds associated with a southeastward-moving Mongolian cyclone,a severe transmission line galloping occurred in Baiyin City,Gansu Province,on 14 April 2020.This caused a tripping incident of the t... Influenced by strong winds associated with a southeastward-moving Mongolian cyclone,a severe transmission line galloping occurred in Baiyin City,Gansu Province,on 14 April 2020.This caused a tripping incident of the transmission line in this region.Based on the hourly,0.5°×0.5°,ECMWF ERA5 reanalysis data,this study investigated the formation mechanisms of the Mongolian cyclone and its associated strong winds.Results from the vorticity budget indicate that the convergence-related vertical stretching and the upward transport of cyclonic vorticity governed formation of the Mongolian cyclone in this event;whereas,tilting and export of cyclonic vorticity from the central region of the cyclone mainly decelerated the cyclone’s formation.The kinetic energy(KE)budget shows that the wind associated with the Mongolian cyclone was mainly enhanced by the positive work of the pressure gradient force.Unlike some typical strong wind events in Northwest China,during this event,no significant downward momentum transportation from the upper troposphere was found.The vertical transport of KE exerted a slightly favorable effect on the KE increase around the location where the transmission line galloping trip appeared.In contrast,the horizontal transport mainly caused an export of KE from this region,which applied an overall negative effect on the wind enhancement associated with the Mongolian cyclone. 展开更多
关键词 Mongolian cyclone Kinetic energy State grid Transmission line galloping trip
暂未订购 下载PDF
Impacts of flexible obstructive working environment on dynamic performances of inspection robot for power transmission line 认领 引用 被引量:11
19
作者 肖晓晖 吴功平 +1 位作者 杜娥 李三平 《Journal of Central South University of Technology》 2008年第6期869-876,共8页
The rigid-flexible coupling dynamic modeling and simulation of an inspection robot were conducted to study the influences of the flexible obstructive working environment i.e. overhead transmission line on the robot's... The rigid-flexible coupling dynamic modeling and simulation of an inspection robot were conducted to study the influences of the flexible obstructive working environment i.e. overhead transmission line on the robot's dynamic performance. First, considering the structure of the obstacles and symmetrical mechanism of the robot prototype, four basic subactions were abstracted to fulfill full-path kinematic tasks. Then, a multi-rigid-body dynamic model of the robot was built with Lagrange equation, whil^e a multi-flexible-body dynamic model of a span of lin~ was obtained by combining finite element method (FEM), modal synthesis method and Lagrange equation. The two subsystem models were coupled under rolling along no-obstacle segment and overcoming obstacle poses, and these simulations of three subactions along different spans of line were performed in ADMAS. The simulation results, including the coupling vibration parameters and driving moment of joint motors, show the dynamic performances of the robot along ftexibile obstructive working path: in flexible obstructive working environment, the robot can fulfill the preset motion goals; it responses slower in more flexible path; the fluctuation of robot as well as driving moment of the corresponding joint in startup and brake region is greater than that in rigid environment; the fluctuation amplitude increases with increasing working environment flexibility. 展开更多
关键词 inspection robot transmission line obstruction rigid-flexible coupling dynamics finite element method simulation
暂未订购 下载PDF
Mechanical response of transmission lines based on sliding cable element 认领 引用 被引量:5
20
作者 刘云 钱振东 夏开全 《Journal of Central South University》 SCIE EI CAS 2014年第8期3370-3377,共8页
In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding ca... In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding catenary element considering the out-of-plane stiffness coefficient are put forward.A two-span and a three-span cable structures are taken as examples to verify the sliding cable elements.By comparing the tensions of the two proposed cable elements with the existing research results,the error is less than 1%,which proves the correctness of the proposed elements.The sliding characteristics should be considered in the practical engineering because of the significant difference between the tensions of sliding cable elements and those of cable element without considering sliding.The out-of-plane stiffness coefficient and friction characteristics do not obviously affect the cable tensions. 展开更多
关键词 transmission lines sliding cable element updated Lagrangian formulation geometric nonlinearity mechanical response
暂未订购 下载PDF
上一页 1 2 16 下一页 到第
在线咨询 使用帮助 返回顶部 意见反馈